The foundational grant. Claims the device and how it is used: a labelled sensor molecule on a surface, a tethered labelled analogue, and detection of the target by the fall in fluorescence as it displaces the analogue. Covers reading concentration from the time curve, several analytes on one surface, unprepared samples and volumes under a microlitre.
Read the patentA measurement that happens at the surface, not in the sample.
qLMI, Quantum-Labelled Molecular Interaction, reads a molecule by watching it take its place in a receptor. One drop goes onto a chip. A quantum dot and a dye report what happens in the first few billionths of a metre above the surface, and the rest of the sample never gets in the way.
MiniLab is in development. It has not been cleared or approved by the U.S. FDA and is not available for sale.
A receptor, a tethered copy and a light that fades.
The method is set out in our granted patents. Each test site on the chip is built from two components that start out locked together and glowing.
A labelled receptor
A sensor molecule with a binding site for the target is fixed to the chip through a quantum dot. The dot is attached where it does not interfere with binding.
A tethered copy
A dye-labelled analogue of the target sits in the binding site, held on a linker. Bound, the dye is close enough to the dot to light up through energy transfer.
Displacement
When the sample arrives, real target molecules take the binding site. The copy swings away on its tether, energy transfer stops and the dye signal falls.
Concentration from the curve
The reader records the signal over time. How fast it falls gives the concentration, so the answer comes from the start of the reaction.
Why the sample does not matter
Energy transfer only works over a few nanometres, so the reading comes from a layer that thin at the chip surface. Colour, cloudiness and thickness of the sample above it do not change the result, and nothing has to be removed first.
US 12,553,890 · claims 17, 19, 20Why one drop is enough
Because the measurement is at the surface, the chip needs very little liquid. The patents cover samples of no more than a microlitre.
US 11,650,205 · claim 16Why tests do not interfere
Each tether is sized so a copy cannot reach a neighbouring receptor. Different tests carry different colours, so several share one surface and are read together.
US 12,553,890 · claims 8, 12 to 14Inside MiniLab.
The patents describe three working parts: a light source, a detector and a controller that records the signal over time. The MiniLab design packages them into a palm-sized reader.

AI-generated illustration based on our internal engineering documents. Labels and details are indicative and may differ from the final design.
Light in
An excitation LED array lights the chip at the wavelength the quantum dots absorb. Optics carry the returning light to the detector.
Photons counted
A photon-counting detector separates each test by its emission colour and follows every signal as it changes, second by second.
Result out
The controller turns each curve into a concentration and sends it to the phone app. The cartridge slot reads which panel has been inserted.
A simple carrier for a sophisticated surface.
The chemistry lives on the chip. The cartridge only has to bring one drop to it and present it to the reader, which is what keeps each test small and single-use.

AI-generated illustration based on our internal engineering documents. Labels and details are indicative and may differ from the final design.
One drop, one port
A fingerstick drop goes into the sample port. A hinged cover keeps the port clean before and after use.
A chip for each test
Each chip in the array carries the receptors for one biomarker. Changing the set of chips changes the panel, with no change to the reader.
Read through the window
The reader lights the chips and collects their signal through a clear window layer. There are no pumps, valves or reagents to add.
Three granted U.S. patents: the device, the chip and the method.
All three are titled "Selective optical detection of organic analytes in liquids" and share a priority date of 11 February 2019. Between them they claim the device, the chip surface and the method, so the protection is not tied to one analyte or one product.
Claims the assay substrate itself, the chip surface at the heart of every cartridge: a sensor molecule labelled with a quantum dot and fixed to the surface, with a dye-labelled analogue tethered to the same dot. Also covers several analytes on one surface, the sample compartment that limits volume and layer thickness, and systems that pair the substrate with a light source, detector and controller.
Read the patentClaims the method on its own, written around a quantum dot and a fluorescent dye. Adds claims to recording the time curve in repeated excitation and detection cycles, several analogues sharing one quantum dot, multichannel and multispectral reading, a sensor molecule that is a protein or an oligonucleotide, and detection that is independent of sample impurity, viscosity and opacity.
Read the patentDesigning receptors from the body's own binding sites.
A qLMI test is only as good as its receptor. These three peer-reviewed papers, co-authored by inventors of the qLMI patents at the University of Tartu, show the approach on the SARS-CoV-2 spike protein: start from the human protein the virus binds, find the short fragment that does the binding, then test it.
- 2020
Mapping of ACE2 binding site on SARS-CoV-2 spike protein S1: docking study with peptides
A. Kuznetsov and J. Järv · Proceedings of the Estonian Academy of Sciences, 69(3), 228–234
A computational study of peptides taken from ACE2, the human protein the virus attaches to. It shows that shortened fragments still bind the spike protein, identifying candidates for further development.
Read the paper - 2020
Mapping the ACE2 binding site on the SARS-CoV-2 spike protein S1: molecular recognition pattern
A. Kuznetsov and J. Järv · Proceedings of the Estonian Academy of Sciences, 69(4), 355–361
Each amino acid of the lead peptide is swapped in turn to find which positions matter for binding. The result is a position-by-position map of how the spike protein recognises its target.
Read the paper - 2022
ACE2 peptide fragment interaction with different S1 protein sites
A. Kuznetsov, P. Arukuusk, H. Härk, E. Juronen, M. Ustav, Ü. Langel and J. Järv · International Journal of Peptide Research and Therapeutics, 28(1), 7
Laboratory kinetics with a 19-amino-acid ACE2 fragment. Pre-incubating the spike protein with the peptide inhibited its binding to ACE2, and computational mapping revealed two further peptide binding sites on the protein.
Read the paper
Links go to the publishers. The papers examine these peptides as potential antiviral inhibitors; we apply the same receptor-design approach to detection.
What has been measured, and what is still ahead.
Measured today
- Estradiol quantified in serum from 100 pM to 10 nM, r² = 0.99.
- Under 5% error across more than 100 serum samples.
- A quantitative result in 3 to 5 minutes, from less than a microlitre at the read surface.
Still ahead
- The reader and cartridge pictures on this page are AI-generated illustrations of the design, not photographs of finished products.
- The core four-hormone cartridge is in development; further panels need their own receptors and validation.
- No Qanik DX product has been cleared or approved by the FDA or any other regulator.
Take the platform further.
We are talking with diagnostics companies and investors about bringing MiniLab and BioSafety to market. If the method fits a measurement you care about, tell us.
- →What it can measure: see the applications
- →Who we are: about Qanik DX